SACE Tmax XT
Simply XTraordinary
Tmax XT moulded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety. Range is complete with four frame sizes: XT1, XT2 up to 160A and XT3, XT4 up to 250A.
XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions.
A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios.
Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system.
Wide range of keylocks and padlocking options, plug in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers’ status.
SACE Emax 2
From circuit breaker to power manager
SACE Emax 2 air circuit breakers up to 6300A have been designed to increase efficiency. It is the only breaker that protects electrical circuits and also reduces energy consumption based on the user's needs, therefore leading to massive reductions in energy waste.
The breaker contains a protection trip relay with an integrated power controller that measures and evaluates energy consumption, managing the loads to maintain or reduce the peak power usage.
Miniature circuit breakers - MCBs
Uncompromising safety and comfort
Miniature circuit breakers protect installations against overload and short-circuit, warranting reliability and safety for operations. System pro M compact S 200 series are current limiting overcurrent protective devices. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection.
SACE FORMULA
Formula for you. Get quality easily.
SACE FORMULA range consists of three frame sizes: A1, A2 and A3 up to 630A.
Fixed thresholds on trip units, pre-cabled version of accessories and FORMULA link save time putting FORMULA in service.
1,2,3, and 4 poles versions up to 250A, no derating up to 50°C and common range of click-in accessories
Extremely compact dimensions and coordinated depths mean standardized dimensions and savings in distribution boards design.
ABB Circuit Breakers
SACE Tmax T
A complete range of moulded case circuit-breakers up to 3200 A.
All the circuit-breakers, both three-pole and four-pole, are available in the fixed version; sizes T4 and T5 in the plug-in version and T4, T5, T6, and T7 also in the withdrawable one.
High values of short circuit breaking capacity are guaranteed at different voltage levels, without compromising overall dimensions.
Thermomagnetic and electronic trip units are available for use in AC/DC or in AC only. It is possible to interchange trip units keeping the same breaking part, so that installation can be upgraded with fewer costs.
A complete range of electronic trip units is suitable for different level of protection, even enhancing selectivity values with Early Fault Detection and Prevention algorithm.